CHAPTER 68    Configuration Parameters Reference
CAS State Machines Parameters
Note: To configure the CAS State Machine table using the Web interface, see
State
Machines. The CAS state machine can be configured only through the Web-based
management tool.
'Generate Digit On Time'
[CASStateMachineGenerateDigitOnTime]
'Generate Inter Digit Time'
[CASStateMachineGenerateInterDigitTime]
'DTMF Max Detection Time'
[CASStateMachineDTMFMaxOnDetectionTime]
'DTMF Min Detection Time'
[CASStateMachineDTMFMinOnDetectionTime]
'MAX Incoming Address Digits'
[CASStateMachineMaxNumOfIncomingAddress
Digits]
'MAX Incoming ANI Digits'
[CASStateMachineMaxNumOfIncomingANIDigi
ts]
'Collect ANI'
[CASStateMachineCollectANI]
Parameter
- 1274 -
Mediant 1000 Gateway & E-SBC | User's Manual
Description
Note: For the parameter to take effect, a
device reset is required.
Generates digit on-time (in msec).
The value must be a positive value. The
default is -1.
Generates digit off-time (in msec).
The value must be a positive value. The
default is -1.
Detects digit maximum on time (according
to DSP detection information event) in
msec units.
The value must be a positive value. The
default is -1.
Detects digit minimum on time (according
to DSP detection information event) in
msec units. The digit time length must be
longer than this value to receive a
detection. Any number may be used, but
the value must be less than
CasStateMachineDTMFMaxOnDetection
Time.
The value must be a positive value. The
default is -1.
Defines the limitation for the maximum
address digits that need to be collected.
After reaching this number of digits, the
collection of address digits is stopped.
The value must be an integer. The default
is -1.
Defines the limitation for the maximum
ANI digits that need to be collected. After
reaching this number of digits, the
collection of ANI digits is stopped.
The value must be an integer. The default
is -1.
In some cases, when the state machine
handles the ANI collection (not related to
MFCR2), you can enable the state
machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
Configuring CAS