CHAPTER 29    Analog Gateway

Configuring Metering Tones

The FXS interfaces can generate 12/16 KHz metering pulses toward the Tel side (e.g., for
connection to a pay phone or private meter). Tariff pulse rate is according to the device's Charge
Codes table. This capability enables users to define different tariffs according to the
source/destination numbers and the time-of-day. The tariff rate includes the time interval between
the generated pulses and the number of pulses generated on answer.
To configure metering tone type:
1.
Open the Analog Settings page (Setup menu > Signaling & Media tab > Gateway folder >
Analog Gateway > Analog Settings).
2.
From the 'Analog Metering Type' drop-down list (MeteringType), select the metering pulse
generated toward the Tel side.
3.
In the 'Analog TTX Voltage Level' field (AnalogTTXVoltageLevel), configure the metering
signal/pulse voltage level.
4.
Click Apply, and then reset the device with a save-to-flash for your settings to take effect.

Configuring FXO Settings

The FXO Settings page lets you configure the device's specific FXO parameters. For a description
of these parameters, see
The FXO Settings page is applicable only to FXO interfaces.
To configure the FXO parameters:
1.
Open the FXO Settings page (Setup menu > Signaling & Media tab > Gateway folder >
Analog Gateway > FXO Settings).
The Metering Tones page is applicable only to FXS interfaces.
Charge Code rules can be assigned to routing rules in the Tel-to-IP Routing table
(see
Configuring Tel-to-IP Routing
to-IP Routing table is searched for the destination IP address. Once a route is
located, the Charge Code (configured for that route) is used to associate the route
with an entry in the Charge Codes table.
Configuration Parameters
Mediant 1000 Gateway & E-SBC | User's Manual
Rules). When a new call is established, the Tel-
Reference.