CHAPTER 59    Self-Testing
59

Self-Testing

The device features the following self-testing modes to identify faulty hardware components:
Detailed Test (Configurable): This test verifies the correct functioning of the different
hardware components on the device. This test is done when the device is taken out of service
(i.e., not in regular service for processing calls). The test is performed on startup when
initialization of the device completes.
To enable this test, set the ini file parameter, EnableDiagnostics to 1 or 2, and then reset the
device. Upon completion of the test and if the test fails, the device sends information on the
test results of each hardware component to the Syslog server.
The following hardware components are tested:
DSPs - when EnableDiagnostics = 1 or 2
Analog interfaces - when EnableDiagnostics = 1 or 2
Startup Test (automatic): This hardware test has minor impact in real-time. While this test is
executed, the regular operation of the device is disabled. If an error is detected, an error
message is sent to the Syslog.
To return the device to regular operation and service, disable the test by setting the
ini file parameter, EnableDiagnostics to 0, and then reset the device.
While the test is enabled, ignore errors sent to the Syslog server.