Setting And Accessing Communication Parameters - Delta ASDA-B2-F Series User Manual

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

ASDA-B2-F

8.4 Setting and Accessing Communication Parameters

For parameter details, please refer to Chapter 7. Descriptions of parameters which can be
written or read via communication are as follows.
Parameters are divided into 6 groups:
Group 0: Monitor Parameters
Group 1: Basic Parameters
Group 2: Extension Parameters
Group 3: Communication Parameters
Group 4: Diagnosis Parameters
Group 5: Motion Setting
Setting parameters via communication:
Parameters which can be written via communication include:
Group 0, except (P0-00), (P0-08~P0-13), (P0-44, P0-46) and (P5-50~P0-52)
Group 1 (P1-00~P1-76)
Group 2 (P2-00~P2-71)
Group 3 (P3-00~P3-12)
Group 4, except (P4-01~P4-04) and (P4-08~P4-09)
Group 5, except (P5-00)
Please note that:
(P3-01) While changing to a new communication speed, the next data will be written in the new
transmission speed after the new value is set.
(P3-02) While changing to a new communication protocol, the next data will be written with the
new communication protocol after the new value is set.
(P4-05) JOG control parameters. For writing method, please refer to chapter regarding
parameters and its function.
(P4-06) Forced DO control (Digital Output Register (Readable and Writable)). This parameter is
for DO (Digit Output) testing. Users can write in 1, 2, 4, 8, and 16 to test DO1, DO2, DO3,
DO4 and DO5 respectively. Please write 0 after the test so as to inform the servo drive
that the test has been completed.
(P4-10) Adjustment selection. Set P2-08 to 20 (= 14H, in hexadecimal format) first to enable the
function, and then write the value of P4-10.
(P4-11~P4-21) This parameter is for offset adjustment. Do not change the setting unless it is
necessary. If it is necessary, please write 22 (= 16H, in hexadecimal format) in
parameter P2-08 first to enable the function so as to write the value of P4-11 ~ P4-21.
Accessing parameters via communication:
Parameters which can be read via communication include:
Group 0 (P0-00~P0-55)
Group 1 (P1-00~P1-76)
Group 2 (P2-00~P2-71)
Group 3 (P3-00~P3-12)
September, 2015
Group 4 (P4-00~P4-24)
Group 5 (P5-00~P5-35)
Communications
8
8-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents