Resonance Suppression - Delta ASDA-B2-F Series User Manual

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Control Mode of Operation

6.3.6 Resonance Suppression

When resonance occurs, it is probably because the stiffness of the control system is too strong
or the response bandwidth is too fast. Eliminating these two factors might improve the situation.
In addition, low-pass filter (P2-25) and notch filter (P2-23 and P2-24) are provided to suppress
6
the resonance without changing the control parameters.
Relevant Parameters (Please refer to Chapter 7 for detailed description):
Parameter
Differentiator
There are two sets of notch filter for auto resonance suppression, one is P2-43 (resonance
frequency) and P2-44 (attenuation rate) and the other one is P2-45 (resonance frequency) and
P2-46 (attenuation rate). When the resonance occurs, set P2-47 to 1 or 2 (enable the function of
auto resonance suppression), the servo drive will search for the point of resonance frequency
and suppress the resonance automatically. This function will write the frequency point into P2-43
and P2-45 and the attenuation rate into P2-44 and P2-46. When P2-47 is set to 1, the system will
set P2-47 to 0 (disable the function of auto suppression) automatically after resonance
suppression is completed and the system is stable for 20 minutes. When P2-47 is set to 2, the
system will keep searching for the resonance point.
When P2-47 is set to 1 or 2, but the resonance still exists, please check the value of parameter
P2-44 and P2-46. If the one of the value is 32, it is suggested to reduce the speed bandwidth first
and then start to estimate it again. If the both value are smaller than 32 and the resonance still
exists, please set P2-47 to 0 first and then manually increase the value of P2-44 and P2-46. If
the resonance situation has not been improved, it is suggested to reduce the bandwidth and then
use the function of auto resonance suppression.
When manually increase the value of P2-44 and P2-46, please check if the value of both are
6-18
Abbr.
P2-23
NCF1
Resonance Suppression (Notch Filter) (1)
P2-24
DPH1
Resonance Suppression (Notch Filter) Attenuation Rate (1)
P2-43
NCF2
Resonance Suppression (Notch Filter) (2)
P2-44
DPH2
Resonance Suppression (Notch Filter) Attenuation Rate (2)
P2-45
NCF3
Resonance Suppression (Notch Filter) (3)
P2-46
DPH3
Resonance Suppression (Notch Filter) Attenuation Rate (3)
P2-25
NLP
Low-pass Filter of Resonance Suppression
Speed Feed
Forward Gain
Low-pass
P2-07
Filter
P2-25
PI Controller
P2-04, P2-
06
Notch Filter 1
P2-23, P2-24
Figure 6-9 Resonance Suppression
Function
Speed Control Unit
Notch Filter 2
P2-43, P2-44
Auto Resonance Suppression
Mode Setting and Resonance
Suppression Detection Level
P2-47, P2-48
Speed
Estimator
Current
Sensor
Notch Filter 3
Current
Controller
P2-45, P2-46
PWM
Torque
Load
ASDA-B2-F
Motor
Encoder
September, 2015

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents