5.3 JOG Trial Run without Load

It is very convenient to test the motor and servo drive with the method of JOG trial run without
load since the extra wiring is unnecessary. For safety reasons, it is recommended to set JOG at
low speed. Please see the following descriptions.
Step 1: Use software setting to Servo On the drive. Set parameter P2-30 to 1. This setting is to
force servo on the drive through software.
Step 2: Set P4-05 to JOG speed (Unit: r/min). After setting the desired JOG speed, press the
SET key, the servo drive will enter JOG mode.
Step 3: Press the MODE key to exist JOG mode.
Speed 0
If the motor does not run, please check if the wiring between UVW and encoder cable is correct.
If the motor runs abnormally, please check if the UVW phase sequence is correct.