Panel Display and Operation

4.4.5 Digital Output Diagnosis Operation

Enter the Diagnosis Mode – DO by the following setting methods. The output signal DO1 ~ DO2
is ON and the corresponding signal will be shown on the panel. It is displayed by bit. When it
4
shows 1, it means the DO is ON.
For example, if it shows 03, 3 is in hexadecimal format, it will be 0011 when it transfers to binary
format. Then, DO1~DO2 is ON.
4-14
SET
The panel displays in
hexadecimal format.
0000 0011
DO
DO
2
1
(Display in hexadecimal format)
Binary Code
Corresponding
DO Status