Absolute Type Of Battery Box And Wiring Rods; Specifications - Delta ASDA-B2-F Series User Manual

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

ASDA-B2-F

10.1 Absolute Type of Battery Box and Wiring Rods

10.1.1 Specifications

Precautions
Please carefully read through the following safety precautions. Use batteries in accordance with
the specification so as to avoid damages or dangers.
The installation location shall have no water drop, corrosive gas and inflammable
gas.
Correctly place the battery into battery box so as to avoid short circuiting.
Do not short circuit the positive electrode and negative electrode of the battery;
or install the battery in reverse direction.
It is suggested to use new batteries only. This is for avoiding losing electric
energy or shortening the lifetime of new batteries.
Please follow the instructions when conduct wiring for battery box, or danger
may occur.
Do not place the battery in a high-temperature environment (over 100℃) or it
might result in fire or explosion.
It is non-rechargeable batteries. Do not charge the batteries or it might result in
explosion.
Do not directly weld on the surface of the battery.
Battery Specifications
Maximum Continuous Discharge Current
September, 2015
Items
Type
Delta Model Number
International Standard Size
Standard Voltage
Standard Capacity
Maximum Pulse Current
Dimensions (D x H)
Weight
Operating Temperature
Li/SOCl2 Cylindrical Battery
ER14505
ASD-CLBT0100
AA
3.6 V
2700 mAh
100 mA
200 mA
14.5 x 50.5 mm
Approx. 19 g
-40~+85 ℃
Absolute System
10
10-3

Hide quick links: