Each Part Of The Servo Drive - Delta ASDA-B2-F Series User Manual

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

ASDA-B2-F
1.4

Each Part of the Servo Drive

Heat sink:
Used to secure servo drive and for heat dissipation.
Control Circuit Terminal (L1c、L2c):
Used to connect 200 ~ 230 V
Main Circuit Terminal (R, S, T):
Used to connect 200 ~ 230 V, 50 / 60 Hz commercial power supply.
Servo Motor Output (U, V, W):
Used to connect servo motor. Never connect the output terminal to main circuit power.
The AC servo drive may be destroyed beyond repair if incorrect cables are connected to the
output terminals.
Regenerative Resistor:
(1) When using an external regenerative resistor, connect P⊕ and C to the regenerative
resistor and ensure that the circuit between P⊕ and C is open.
(2) When using the internal regenerative resistor, ensure that the circuit between P⊕ and D
is closed and the circuit between P⊕ and C is open
CN6: DMCNET Connector: Communication port for DMCNET communication.
CN1: I/O Interface: Used to connect external controller (PLC) or control I/O signal.
CN2: Encoder Interface:
CN3: Serial Communication Interface: It is controlled by MODBUS and supports RS-232.
It can be connected to controllers.
Ground Terminal: Used to connect grounding wire of power supply and servo motor.
Please connect it properly to avoid electric shock.
September, 2015
c, 50 / 60 Hz 1-phase / 3-phase V
A
Used to connect encoder of servo motor.
Inspection and Model Explanation
supply.
AC
1
1-7