ASDA-B3

P3.xxx Communication parameters

P3.000●
Default: 0x007F
Unit: -
Format: HEX
Settings:
UZ
Reserved
The address setting required for using RS-485, CANopen, and DMCNET communication. Make sure
there are no duplicate addresses in the same communication circuit, or it may cause communication
failure.
RS-485
When the master station sets the communication address to 0xFF, the address is always 0xFF in the
response message.
EtherCAT
When P3.018.A = 1, the address refers to the setting of P3.000; when P3.018.A = 0, the address must
be set by the controller.
P3.001●
0x0203 (-L, -M, -E)
Default:
0x3203 (-F)
Unit: -
Format: HEX
Settings:
X
RS-485 transmission speed
Y
Reserved
X: RS-485 transmission speed
Address
Transmission speed
0: 4800 bps
1: 9600 bps
3: 38400 bps
4: 57600 bps
Control mode: All
0x0001 - 0x007F (-L, -M, -F)
Setting range:
0x0001 - 0xFFFF (-E)
Data size: 16-bit
YX
Communication address setting
Control mode: All
0x0000 - 0x0405 (-L, -M, -E)
Setting range:
0x0000 - 0xF405 (-F)
Data size: 16-bit
Z
CANopen / DMCNET / EtherCAT transmission speed
U
DMCNET motion card
2: 19200 bps
5: 115200 bps
Parameters
Address: 0300H
0301H
Address: 0302H
0303H
8
8-105