Galaxy Programming Manual
3 = Setting
The Setting attribute determines the function (if any) that the custom zone has in setting and unsetting the
system.
1.
Begin Set
2.
Begin Entry
3.
Sets System
The default for each of the Setting attributes is disabled. To enable the options, select the required Setting
attribute using the A or B keys and press the # key; the display indicates that attribute is ENABLED for the
custom zone.
NOTE: The custom zone can be assigned all three Setting attributes if required, however, it is recommended
that either attribute 1 (Begin Set) or 3 (Sets System) is enabled, but not both.
4 = Log
This attribute determines which custom zone activations are logged. On selecting Log the current selection is
displayed. To change the selection press the # key, this toggles between the Log options;
Disabled the custom zone activations are not logged,
Entry/Exit the custom zone activations only log during the setting and unsetting procedure,
24 Hours all custom zone activations log (both in the set and unset states)
Alarms
the custom zone only logs when an activation results in an alarm condition.
NOTE:
The opening (+) and closing (–) of custom zones are recorded in the event log.
if enabled, the custom zone starts the setting procedure,
if enabled, the custom zone starts the unsetting procedure,
if enabled, the custom terminates the setting procedure.