Option 46 - Group Omit (Galaxy 18, 60, 128, 500 & 504) - Honeywell Galaxy 18Galaxy Programming Manual

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

Galaxy Programming Manual
46 - Group Omit
Option 46 – Group Omit (Galaxy 18, 60, 128, 500 & 504)
This option allows a level 6 user code to block omit all the omittable zones that are open at the end of the
confirm time in a group or multiple groups. All zones in the required groups that have the omit attribute ena-
bled (refer to option 52.4 = PROGRAM ZONES.Omit) are omitted when this option is selected. Groups
can be omitted and reinstated without setting and unsetting the system.
On selecting the Group Omit Option the groups assigned to the user code and keypad are displayed as well
as the omit status of each group (Y below the group indicates that it is omitted, N indicates that it is not omit-
ted). To omit a group, press the required key. The letter beneath the group number changes from N to Y. To
reinstate the group press the key to toggle from Y to N.
NOTE: The level 6 user must have group choice to enter Group Omit.
NOTE: The zones in the selected groups are omitted from the system as soon as the group is selected.
On returning to the banner (normal or engineer) the keypad displays the message ZONES OMITTED.
Omitted zones remain omitted for one set period only or until they are manually reinstated to the system.
Galaxy 18, 60, 128, 500 & 504
Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as the zone is
omitted and remains active until the zone is reinstated. If the output mode is programmed as latch, then the
Zone Omit outputs activate when the system is set and remain active until the system is unset — reinstating
the omitted zones.
44

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents