53 - Program Outputs (cont'd)
51 – 65 Link A – O (Reflex)
Link output types have no inherent function: they are designed for use with option 54 = LINKS to provide the
engineer with a means of activating a specific output address.
Link outputs can be activated by any of the link option sources. The operation of the Link output is depend-
ent on the Output Mode and Groups assigned to the output.The Groups assigned to the Link must have at
least one group common to the link output, if that output is to be activated. This feature can be used to multi-
ply the number of different link outputs available on the system.
NOTE: When a zone function is the source of a Link output type, then a point to point link is available and
is as effective as direct wiring.
66 RF Jam (Latch)
The RF Jam output is activated whenever any of the RF RIO's configured onto the system detect a significant
level of interference to cause radio jamming.
67 RF Super (Latch)
The RF Supervision output is activated whenever there is a supervision failure from any one of the super-
vised RF detectors configured onto the system. That is, when the system has received no signals (including
periodic check-in signals) whatsoever, from a particular detector within the programmed supervision period.
68 – 69 Not Used
70 Lockout (Reflex) (Galaxy 512)
The Lockout output is active between the ON and OFF times assigned to the Lockout Status (option
65.3.6=TIMERS.Autoset.Lockout Status). The Lockout output mode is Reflex, therefore it remains
active until the lockout switches OFF.
71 Vibration Test (Pulse) (Galaxy 504 & 512)
The Vibration Test function is used to test zones programmed as Vibration. This output is used in conjunc-
tion with Precheck (menu option 66 – Pre-Check: - Mode: 4 – Forced Check). The Vibration Test output
sends a five second positive removed pulse to the vault sensors. Any sensor not activated by the test is re-
ported by the pre-check function and prevents the system from setting.
72 – 75 ATM-1, ATM-2, ATM-3, ATM-4 (Reflex) (Galaxy 512)
The relevant ATM output is activated when the respective ATM zone type is selected for omission; the
output does not wait until the ATM Delay period expires before it activates. This output is a Reflex output
and follows omit status of the ATM zone types.