Option 49 - Datelock (Galaxy 512) - Honeywell Galaxy 18Galaxy Programming Manual

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

Galaxy Programming Manual
Option 49 – Datelock (Galaxy 512)
The Datelock option allows the system to be set and prevented from unsetting until the date and time speci-
fied by the user. This option can only be accessed by level 6 user codes with access to all groups. The
Datelock menu option can only be accessed if parameter 40 — Datelock has been enabled.
NOTE: This option can only be selected by level 6 users. The level access Datelock cannot be modified
using menu option 68 — Menu Access.
On selecting this option the user is prompted to enter the Date (day, month and year) and the Time (hours
and minutes) when the panel will be unlocked. The date and time entered must be valid and also be some time
in the future - 31/02/96 will be rejected as an invalid date.
The system then prompts for another code (level 3 or above) to be entered to confirm the Date and Time
entered by the level 6 user code. To confirm the time and date press the A key (A = YES). To reject the
programming press the B key (B = NO). If the esc key is pressed or a keypad timeout occurs, the
Datelock is cancelled.
Once the second user has confirmed the Date and Time, the system immediately starts to set. If menu option
66.4 = PRE-CHECK.Forced Check is enabled all of the zones on the system must be verified as being
operational by opening and closing each zone. This also activates the Vibtest output to pre-check the opera-
tion of all Vibration zones before the system sets. Once set, all codes are locked out until the programmed
Datelock date and time. The system can not be unset manually.
During the Datelock period, all outputs programmed as Lockout are active. Once the programmed
Datelock expires the codes are re-enabled. The system can only be unset by entering any 2 valid codes.
During the Datelock period, the system rearms indefinitely. On rearming, any zone that is currently open or
has alarmed twice is omitted whether or not it is omittable.
In the event of an alarm occurring, if the Datelock parameter is set to 2, entry of 2 valid codes with access to
all groups will unset the system before the programmed Datelock period has expired.
NOTE: After a warm start, the system removes any outstanding Datelock period to provide a means of
cancelling it.
49 - Datelock
47