Honeywell Galaxy 18Galaxy Programming Manual page 86

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

Galaxy Programming Manual
52 - Program Zones (cont'd)
On entering an ATM code, the system prompts for one of the ATM zone types to be selected; to select the
ATM zone type to be omitted use the A or B key or enter the number of the ATM zone type. Once the zone
is selected, the keypad indicates the DELAY ACCESS - the number of minutes remaining until the ATM
zones are omitted. Once the zone is omitted, the initiating keypad indicates the ACCESS TIMEOUT - the
number of minutes remaining until the selected ATM zones are reintroduced to the system. The Entry/Exit
Horns sound a warning ten and five minutes before the zones are reinstated.
The omitted ATM zone type can be reinstated at any time, or the omit period can be extended by the ATM
user code. Enter the ATM code and press the ent key; the system prompts for 1 = RESET ACCESS or 2
= ABORT ACCESS. Press 1 to restart the ATM Timeout or 2 to reinstate the omitted ATM's.
NOTE: Only one ATM zone type may be omitted at any time.
52 Alarm Extend (G18, 60, 128, 500, 504 & 512)
The Alarm Extend function is identical to the Urgent function, with the exception that if the zone is open (and
has not been previously omitted) at the end of the bell duration (refer to option 51.1 = PARAMETERS.Bell
Time) it immediately activates another full alarm condition. Alarm Extend zones can only be omitted by
option 11 = OMIT ZONES.