65 - Timers (cont'd)

Timer A and B

The Galaxy 18, 60, 128, 500, 504 and 512 control panels provide 2 timers that allow up to 20 times to be
assigned over a 7 day period; these can be combined in any order of On and Off times as required.
Programming Timers
1. Enter the Timers option; 1=TIMER A is displayed. To modify or assign times go to Step 5.
2. Press the ent key to select Timer A or the A then ent keys to select Timer B; 1=TIMER STATUS is
displayed.
3. Press the ent key; the status of the selected timer is displayed (the default setting is 0=OFF). To change
the status press the A or B key or press key 1 to select ON or 2 to select OFF.
4. Press the ent key to accept the programming and return to the previous menu level. Press the esc key
once to return to 1=TIMER A, or twice to escape from the option.
5. To modify the times, press the ent key to select Timer A or the A then the ent keys to select Timer B;
1=TIMER STATUS is displayed.
6. Press the A then ent key to select 2=TIMERS (1–20); the first 2 times assigned to the timer are
displayed (the first time is on the top line, the second is on the bottom).
7. Press the A key to step through each of the times until the required time is displayed on the top line of the
display.
8. Press the ent key to select the time to be modified:
the
key deletes the programmed time information;
the A or B keys change the programmed day;
the # key toggles whether the timer switches ON or OFF;
the number keys (0–9) assign the time (the time must be four digits in the 24 hour format);
9. Press the ent key to accept the programming and return to the previous menu level.
10. Press the esc key three times to escape from the Timers option.
Once the times have been programmed and the Timer Status is set to 1=On, the Timer-A or Timer-B
outputs are activated at the programmed On times and deactivated at the Off times. User codes that they
have been attributed to a Time Zone A or B are invalid between an On time and the next Off time for the
appropriate timer.
NOTE: The Timer Status can be switched On and Off by users via option 45 = TIMER CONTROL.
Galaxy Programming Manual
A
MON ON
19:30
TUE OFF 07:30
A
MON ON
19:30
[<],[>],#,0-9,*
156