54 - Links
Option 54 – Links (Galaxy 18, 60, 128, 500, 504 & 512)
The Links offers a powerful method of interconnecting zones, output functions, codes, keypads, and MAX
modules. The links table is constructed by creating a link between one of the source types and a valid destina-
tion type. Activating the source of a link activates the destination – this can be used to switch outputs on and
off to omit zones, codes, keypads and MAX modules from the system.
The links function allows MAX/MicroMAX/MAX
destination is programmed as MAX/MicroMAX/MAX
MicroMAX/MAX
3
door relay will open for the duration the link is active. During this period no MAX alarms
are generated if the door contact timeout is exceeded. The on-board horns are deactivated and the green
open LED will be illuminated throughout.
When the link is deactivated the MAX/MicroMAX/MAX
the programmed relay duration period. - simulates an egress button activation.
If a max is disabled as the destination of a link, a card swiped at the max will still cancel an alarm or unset the
system. However it will not activate the relay or do a max function.
The number of links that can be assigned on each of the Galaxy systems is:
• Galaxy 18
• Galaxy 60
• Galaxy 128 = 128
• Galaxy 500 = 256
• Galaxy 504 = 256
• Galaxy 512 = 256

Programming Links

On selecting the Links option, the details of Link 01 are displayed. If no link has been assigned the screen
displays 01 NOT USED.
The details of each link can be displayed using the A and B keys, or a specific link can be selected by entering
the required link number, for example 05, 29. When the required link is displayed, press, the ent key to begin
the programming procedure. The system prompts for the Link Source to be assigned. If groups are set then
some sources and destinations will not be available for programming:
1. Press the # key to select the required link source from the available types (refer to Table 20. Link
Source ).
2. Press the A or B keys to select the actual link source (for example, the zone address or the user code
number).
3. If the source is required to toggle the destination on and off, press the
on the display.
NOTES:
1. The link destination is activated by the first operation of the source and then deactivated by the second
operation.
2. Galaxy 18 does not have full use of links. It can only have an output type as its destination.
4. Press the ent key; the source of the link is assigned and the keypad prompts for the link destination to be
allocated.
5. Press the # key to select the required link destination from the available types (refer to Table 21. Link
Destination).
6. Press the A or B keys to select the actual link destination (for example, the zone address or the output
type). To cancel a link program the source as not used.
7. Press the ent key.
= 32
= 64
Galaxy Programming Manual
3
destinations to be assigned a ( ) star function. If the
3
and the ( ) star is allocated, the assigned MAX/
horn sounds and the door relay remains open for
3
96
key. The source is prefixed by a