Setting Features (cont'd)

Abort Time

Should the user exceed the entry time or stray from the entry route a full alarm occurs. However the activation
of the intruder output can be delayed to allow time for the user to abort the remote signalling.
The Abort Time parameter can also be programmed so that an Intruder alarm is activated immediately the
entry time expires or a zone is activated, but entry of any valid code cancels the alarm and deactivates the
Intruder outputs without the need for a system reset.

Abort Setting Message

Zones that are open or opened during the exit period are indicated to the user by a rapid audible tone from the
entry/exit horns. The keypad displays the open zones and then prompts the user to abort the setting by press-
ing the ESC key. This message is designed to prevent users from re-entering the building, closing the open
zones, allowing the system to set and trapping the user in the building.
Fail to Set – Galaxy 60, 128, 500, 504 & 512
An output type (Option 53-Program output 40, Fail Set) is available that activates if a full set has not
occurred after a programmed period of time (determined by Option 51-Parameter 35, Fail to Set) from the
start of the setting procedure.

Power Failure While System is Set

When power is restored to the system, following a complete mains (a.c.) and standby battery (d.c.) power
failure, the system attempts to return to the set status — full or part — prior to the power failure. The system
begins the setting procedure. If there are no zones open that prevent the system from setting, at the end of the
programmed exit time, the appropriate groups and parts are set.