Option 63 - Options (Galaxy 18, 60, 128, 500, 504 & 512) - Honeywell Galaxy 18Galaxy Programming Manual

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

Galaxy Programming Manual
Option 63 – Options (Galaxy 18, 60, 128, 500, 504 & 512)
The Options function allows the Galaxy to be divided into group subsystems and also allows the MAX
proximity access control readers to be integrated into the system.
Options
1 = Groups
1 = Group Mode
2 = Setting Logic
3 = Group Name
2 = MAX
1 = MAX Mode
2 = MAX Address
3 = MAX Parameters
P
a
n
l e
G
o r
G
8
0
G
8 1
3
G
0 6
4
G
1
8 2
8
G
5
0 0
6 1
G
5
4 0
2 3
G
5
2 1
2 3
Table 25. Groups/Max Modules per Panel
0 = Disabled
1 = Enabled
A/B to move to group and ent to select.
Number keys to toggle:
= status of group uninportant
S = Group must be set to allow group to set.
A/B to move to group and ent to select.
# = toggle upper case, lower case or library text.
∗ = delete last character.
A/B = move to character/word.
ent = assign character/word.
esc = save programming.
0 = Disabled
1 = Enabled
A/B to select line (G500, G504 & G512)
ent to start MAX search.
0 = On-line, ent then key 0 - 7 to readdress MAX.
1 = Standalone
A/B to move to required MAX address.
# to display MAX address graphic.
ent to select.
1 = Descriptor# = toggle upper case, lower case or library text.
∗ = delete last character
A/B = move to character/word
ent = assign character/word
esc = save programming
2 = Relay Duration
1 - 60 seconds (default = 05).
3 = Open Timeout
0 - 60 seconds (default = 10).
4 = Groups
Press group number to toggle group on/off
(G504 & 512) A/B to move between group blocks.
5 = Emergencies
Enable or disable option. If group mode is enabled,
a separate enable is available for each group.
1 = Mode
6 = AntiPassBack
2 = Timout
3 = Forgive
141
63 - Options
u
p
M
x a
2
3
4
8
6 1
2 3
2 3
0 = Off
1 = Soft
2 = Hard
(0 - 60 minutes). Specifies the time that the
antipassback restrictions last for.
Allows the engineer to remove all antipassback
restrictions for the selected MAX. Use the
A>B< keys to select the reader address then
press enter to forgive.
No antipassback restriction.
Access is never denied but any violations
will be recorded in the event log.
No access will be granted for a second
swipe within the antipassback period
following a valid swipe.