Honeywell Galaxy 18Galaxy Programming Manual page 148

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

63 - Options (cont'd)
1=Groups
On selecting Options, the keypad displays 1 = Groups; press the ent key to select this function.
1 = Group Mode
This option is used to enable the Groups function (default is 0 = Disabled). When enabled, the system
options that are eligible for group programming are then made available throughout the menu, otherwise they
do not appear.
Enabling Groups
On selecting 1 = Enabled, press the ent key to accept the programming and return to the previous menu
level.
NOTE: You must return to the Engineer Mode banner for groups to be fully enabled.
Disabling Groups
The Group Disabled feature operates as follows:-
When disable groups is selected in menu option 63.1.1 two option are given:-
1.
Reset Groups
2.
Disabled
If option 1 - Reset Groups is selected the engineer is prompted to confirm the selection. If confirmed, by
pressing the enter key, all group programming, for all the panel features, are reset to A1. When engineering
mode is exited a warning message is displayed (ATT!!! GRPS OFF, SYS. OP. IMPACT) alerting the
engineer that groups have been reset and there will be an impact on the operation of all functions not pro-
grammed as group A1. This warning message will be displayed until the ESC key is pressed by the engineer,
acknowledging the warning.
NOTE: When group programming is re-enabled all previous group programming will not be restored.
If option 2 - Disabled is selected the engineer is prompted to confirm the selection. If confirmed, by pressing
the enter key, all group programming, other than A1 will be disabled (zones, outputs, links, users). When
engineering mode is exited a warning message is displayed (ATT!!! GRPS OFF, SYS. OP. IMPACT)
alerting the engineer that groups have been disabled and there will be an impact on the operation of all areas
not programmed as group A1. This warning message is displayed until the ESC key is pressed by the engi-
neer, acknowledging the warning.
NOTE: If this option is selected, when group mode is re-enabled all previous group programming will be
restored. However, while group mode is disabled, a zone not programmed to group A1 will not
operate normally on the system. It is strongly recommended that, whenever possible, groups are
always reset to A1 when disabling groups.