Honeywell Galaxy 18Galaxy Programming Manual page 85

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

Galaxy Programming Manual
38 PA Unset
This PA Unset function is identical to the PA Silent function, with the exception that it is only operational
when the system is unset; the function is inactive when the group is set.
39 Keyswitch Reset
The Keyswitch Reset function allows alarms to be cancelled and the system to rearm without unsetting the
Galaxy. The level of reset authorisation is determined by the Keyswitch Level (option 51.14). The level
required to reset Intruder, PA and Tamper alarms is determined by the System Reset, Tamper Reset
and PA Reset parameters (option 51.06, 51.07 and 51.22) respectively.
This function is designed to permit a remote signal, for example REDCare's Return Path Signalling feature, to
reset the system following an alarm condition.
47 Vibration (Galaxy 504 & 512)
The Vibration function is continuously operational and is designed for use with vault sensors. Vibration
zones can be block omitted using menu option 11 = Omit Zones. If the zone selected to be omitted from the
system is a Vibration zone, then all zones programmed with this function are omitted.
NOTES
1. All Vibration zones in all groups are omitted when any Vibration zone is omitted. The user code does
not have to have access to all of the groups.
2. Vibration zones remain omitted until a single Vibration zone is manually reinstated. The unsetting of the
system does not reinstate omitted Vibration zones.
48-51 ATM-1, ATM-2, ATM-3 & ATM-4 (Galaxy 512 only)
The Galaxy 512 has four ATM (Automatic Teller Machine) zone types. These zone functions are continuously
operational and are designed for the special maintenance and restocking requirements of ATM's.
A single ATM zone type can be omitted for the duration of the period entered in the ATM Timeout param-
eter (option 51.39). The ATM Delay parameter (option 51.38) determines the delay before the selected
ATM zones are omitted once selected by an ATM code (User 188–197). Each of the zones ATM-1 to
ATM-4 zones activates a corresponding ATM output.
NOTE: The relevant ATM outputs are activated as soon as the ATM zone is selected, not when the ATM
Delay expires.
52 - Program Zones (cont'd)
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents