Omitted Zones

If zones are omitted when the system starts setting, this is indicated on the keypad. The keypad indicates how
many zones are omitted.

Expiry Warning

During the last 25% of the programmed exit time outputs programmed as Entry/Exit Horn begin to pulse
rapidly, indicating that time is running short.

System Set Indication

At the end of the exit time the Entry/Exit Horns become silent for four seconds. This allows the door to be
locked and secured and gives the detectors time to settle before the system finally sets. Two long tones are
emitted to confirm that the system has set. If all groups are set the keypad briefly displays the message SYS-
TEM IS SET before going blank. If any group remain unset the display returns to the banner.

Group Logic Setting Restriction

If Setting Logic has been assigned to a group (refer to 63.1.2 = OPTIONS.Groups.Setting Logic), the set
status of the groups must satisfy the conditions defined in the option to permit the group to set. If the Setting
Logic conditions are not satisfied, then the group cannot set. If multiple groups are being set simultaneously,
but one group is restricted due to the programmed Setting Logic, the remainder of the groups set. The
restricted group does not set; there is no warning or indication given.
If the programmed Setting Logic results in none of the selected groups being allowed to set, a warning
message is displayed on the keypad. This message does not appear if at least one group sets.

Entry Time

The system begins the unsetting routine whenever a Final or Entry zone activates. The Entry/Exit Horns
pulse slowly indicating that the entry time countdown has started. The user must go directly to the keypad,
using the agreed entry route, and unset the system before the entry time expires. When 75% of the entry time
has elapsed the Entry/Exit horns pulse rapidly, indicating that time is running short.

Timeout (Slow Entry)

If the entry time expires before a valid code is entered to unset the group, a full alarm occurs. This is recorded
in the event log as a Timeout against the group which was in the process of being unset.

Straying from the Entry Route

If, during the entry routine, the user strays from the agreed entry route and activates a zone in a protected
area, a full alarm occurs.
2 Groups not set
[<],[>] to view
11
Setting Features (cont'd)