63 - Options (cont'd)
Select the required MAX/MicroMAX address using the A and B keys or by entering the MAX/MicroMAX
address directly and pressing the ent key. The first MAX parameter, 1 = Description is displayed. Use the A
or B keys to move to the required parameter and press the ent key.
1 = Descriptor
This option is used to assign a name of up to 12 characters to each of the MAX modules. This name is assem-
bled from the character set and/or library options. On selecting the Descriptor parameter the currently as-
signed name is displayed on the top line - an underscore shows where the next character will be positioned,
and a selection of the alphabet is shown on the bottom line - the cursor flashes on the letter L.
Press the
key to erase the characters already assigned to the name.
The A or B keys can be used to move the alphabet left or right until the required character is positioned
underneath the flashing cursor. When the required character is in position press the ent key to copy the char-
acter to the descriptor in the top line. Repeat this procedure to assemble the required Descriptor.
Text Case & Library
On entering the Descriptor parameter the alpha-numeric characters are all presented in upper case. Pressing
the # key toggles the characters to lower case.
Pressing the # key when the lower case alphanumeric characters are displayed toggles to the library words.
The words can be viewed using the A or B keys or directly selected using the reference number - refer to
Appendix A - Library. When the required word is displayed, press the ent key to copy it to the name.
Library words are a maximum of 12 characters and upper case only.
2 = Relay Duration
This is the period, following the user card swipe, that the MAX relay is activated allowing a door strike to be
unlocked and the door to be opened without creating an alarm. The MAX relay de-activates as soon as the
door contact opens or the Open Timeout occurs.
On entering the Relay Duration parameter, the current value is displayed; assign the required time within the
range 01 – 60 seconds, the default time is 5 seconds. Press the ent key to save the programming and return
to the previous menu level.
NOTE: Pressing the A key increases the time by one second increments, the B key decreases the time in
one second decrements.