42 - Codes (cont'd)

Escaping from Engineer Mode

1.
Return to the engineer banner.
2.
Enter the engineer code
3.
Press the esc key
The Galaxy begins the exit engineer mode procedure by checking the integrity and security of the system:
CHECKING FOR TAMPERS
standby battery connected to it is capable of operating the system for the required period (as entered in
the Standby Battery parameter — refer to option 51.37). The system then verifies that there are no
tamper conditions present on the panel, the modules or the zones.
SYSTEM MODULES
connected to the system:
If no modules have been added or removed, " NO MODULES ADDED, ESC TO CONTINUE" is
displayed. Pressing esc returns the system to the normal banner.
If modules have been removed they are reported as missing; the engineer is prompted to view the missing
modules and to remove them from the system by pressing the ; a warning is given before the module is
removed. Press the ent key to confirm the removal of the module. Once all missing modules are removed,
the Galaxy reports the previous and current number of modules connected to the system, before returning
to the normal banner.
If modules have been added, the Galaxy reports the previous and current number of modules connected
to the system, before returning to the normal banner.
If the esc key is pressed at any time during the exit engineer mode procedure, the procedure is aborted and
the Galaxy returns to the engineer mode. This return may take several seconds to complete.
Galaxy 512
The engineer is prevented from exiting from engineer mode if a PA zone is open.
Manager Code
The manager is authorised to:
program the User Code options of each of the user codes;
allocate other codes to the manager level (6);
modify the manager PIN — the manager PIN cannot be deleted — and assign the MAX features
to the code.
NOTE: Galaxy 18, 60, 128, 500 & 504 — the manager PIN can be reset to the default code (1234) by
the engineer and remote code using the Reset Mgr (Manager) parameter (refer to option 51.21).
The manager code defaults to group choice when groups are enabled. The manager is able to toggle
the group choice option on and off (using the
— if a Smart PSU is connected to the system, the panel calculates that the
— if there are no tamper conditions the Galaxy checks the number of modules
Galaxy Programming Manual
key) as required.