Mains supply failed
MAINS FAIL
xxx
Fuse identified failed,
OR Output protected by
FUSE x
fuse drawing excessive
FAULT
current
Power supply volts low
LOW VOLTS
xxx
Fault
Description
Engineer
Access to Engineer menu
Access
NOT possible, as system is
Denied
not fully disarmed.
Check Failed
Input in fault on attempting
Input xxx
to exit Engineer mode.
Error input
A input has been
part'ns not
programmed to a partition
accessible
for which no arming point is
valid to disarm.
Error some
Arming points have been
part'ns cannot
programmed such that it is
be disarmed
possible to arm a partition,
but not disarm it.
C H A P T E R 6 : C O N T A C T I N F O R M A T I O N
Address
Pyronix Ltd.
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, UK
customer.support@pyronix.com
Pyronix Ltd. reserves the right to adjust specifications of this system, at any time and without notice, in the
interests of product improvement.
design and manufacture of high-quality security control equipment.
RINS868-6
ENGINEER INDICATIONS
Email:
Pyronix Ltd. is an independent British company specialising in the
PCX 256 PROGRAMMING MANUAL
System detects mains frequency out of
specification, as well as voltage. Note: 'AC FAIL'
timer operative
Fuse 1 = PGMs
Fuse 2 = BELL
Fuse 3 = AUX
Fuse 4 = BATTERY
Fuse 5 = BUS
Battery volts below normal 'battery fault' level
during mains failure
Solution
Ensure that ALL partitions are disarmed, using a
suitable user codes / tags at appropriate keypads /
readers.
Applies to 24-hour tamper, or other input types that
would generate an alarm condition if the system
were returned to disarmed mode.
Also applies to tamper fault on other input types.
Check for fault on input, or omit in programming.
It would therefore be impossible to fully disarm the
system after a tamper alarm on that input.
Programming must be adjusted before exiting
Engineer mode.
Programming must be adjusted before exiting
Engineer mode.
Customer Support line (UK only):
(local rate) Or telephone: 01709 535225
Opening Times
Opening hours: 7:00 AM – 7:30 PM
Monday to Friday
www.pyronix.com
www.dd243.co.uk
Help Line
0845 6434 999
Websites:
Page: 67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents