Sounds To Play; Walk Test - Pyronix PCX-256 Programming Manual

Hide thumbs Also See for PCX-256:
Table of Contents

Advertisement

PCX 256 PROGRAMMING MANUAL
Review Logs
Using the
and
LOGS?' Press the
Panel Log
Press the
key to view the panel log.
You will be returned to the Engineer Menu.
The log will be displayed. Use the
keys to scroll through the log. For more
information on an event (such as alarm silenced
for example) press the
When you wish to exit, press the
Access Log
Repeat the above for the Access log. When you
wish to exit, press the
returned to the Engineer Menu.
5 . 2 0 E n g i n e e r T e s t s
The Engineer Tests function allows the engineer to test inputs, PGM's, batteries and the bell.

5.20.1 Sounds To Play

This function allows you to listen to the different tones the PCX system makes so you can
recognise them. They have a choice of: Chime, Chime Follow, Exit, Exit Fault, Entry, Tech Fault,
Tamper, Alarm, PA, and Fire. (The default is No Sound)

5.20.2 Walk Test

Please note that the walk test feature can only be used when engineer's mode is exited after the
programming of inputs
This function allows the engineer to test all programmed inputs on the system. The inputs that
haven't been activated will be shown on the display. Once all the inputs have been walk tested,
'Walk Test Completed' will be displayed.
When walk-testing a double-knock detector, it must be triggered twice within the preset period.
When testing dual-trip detectors you must first open detector one and then trigger the second
detector; next open the second detector and trigger the first detector.
Page: 50
V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
R E V I E W L O G S
keys, scroll to 'REVIEW
key
and
key.
key.
key. You will be
.
RINS868-6

Hide quick links:

Advertisement

Table of Contents
loading