PCX 256 PROGRAMMING MANUAL
Input Partition
Enter the partitions/level arms you would like the
input to operate in (At default the system is a
level arm system, to change this please refer to
Site Options "Use Level Arm", see page: 47).
NOTE: The primary partitions are A, B, C and D
The default partition selected is A.
Press the
key.
For partition arming systems only:
(Please see common partitioning, page: 18)
Enter
: for Any (Default)
Enter
: for All
Press the
key
Input Attributes
Press the
key to select any attributes for the
input (for details on each attribute see page: 18)
Chime
Enter
: for No (Default)
Enter
: for Single
Enter
: for Follow. Press the
Omittable
Enter
: for No (Default)
Enter
: for Yes
Press the
key. Repeat for Double Knock,
Dual Trip, Normally Open, Monitor Activity (all
defaulted to No) Until:
Special Log
Enter
: for No (Default)
Enter
for Arm
Enter
: for Always, Press the
Paired Input: Do not change. Press
Confirm Group
Enter the Confirm Group if used.
Press the
key