5.4 Install RIXs?

Up to 4 x RIX8i or RIX8+ may be installed on the system. Any Remote Input Expanders (RIXs)
installed on the Enforcer 32-WE system must be enabled in the 'Install RIXs' menu. For installation
details, please refer to the Installation Reference manual.
5.4.1 RIX Address
Select the address of the RIX to enable (Address 0-3).
5.4.2 RIX Installed
Enable/Disable the RIX installed. 1 = Enabled / 0 = Disabled
5.4.3 RIX Location
The location text is stored for reference on later maintenance visits i.e. "GROUND FLOOR". For
information on how to use predictive text, please see page 5.
NOTE: We recommend if adding wired input expander RIX's -to use the version with the PSU
integrated on board, because the Enforcer PSU might be insufficient to power multiple additional
detectors.

5.5 Program Outputs?

This option enables the programming of the outputs on the Enforcer 32-WE and any devices that are
connected.
5.5.1 Endstation PGMs?
These are the outputs on control panel itself. There are 3 outputs on the I/O module of Enforcer –
BELL PGM, STB PGM and PGM. All of them are programmable but the BELL and STB are allocated
to follow the alarm in any area as bell and strobe.
5.5.2 RIX Module PGMs?
These are the outputs that are located in the RIX8+ input expander module, if used. There are 4
PGMs located on this module.
5.5.3 ROX Module PGMs?
This option enables the addition of a wired ROX module to Enforcer as well as programming of the
PGM options for the outputs in the module.
5.5.4 Keypad PGMs?
Allows the programming of the PGM options for the outputs located on the wired keypads.
5.5.5 Reader PGMs?
Allows the programming of the PGM options for the outputs located on the wired readers.
5.5.6 User Outputs?
These outputs are used for creating automation control for Devices. The user can control them
remotely from the user menu on the keypad. The automated user outputs can be programmed
either latched or pulsed.
Polarity of the PGMs: The polarity of the outputs is normally switched negative i.e. in normal status
OFF = 0v and in active status ON = 12v.
NOTE: The PGM Outputs polarity cannot be inverted.
No.
Output Type
0000
Not Used
0001
Fire
0002
PA Any
0003
Burglary Any
0004
Final Arm All
0005
Open After Alarm
(Abort)
0007
Tamper Any
0008
Duress Any
0009
PA Device Any
0010
Gas
Active
At fire alarm activation
At personal attack activation
At burglary alarm from any area
When ALL areas are armed
When system is silenced after 'burglary'
alarm has been activated
Tamper alarm in any area
At a Duress alarm in any area
At alarm on a PA input only from any
area. (This does not include the keypad
PA)
At gas alarm
Page: 13
Restore
When a valid code is entered
When a valid code is entered
At first valid code entry
At code entry to disarm
After 2 minutes
At code entry to silence
When a valid code is entered
When a valid code is entered
When a valid code is entered