Change Outputs - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

4.13.3 Alarm Starts / Stops (Alarm Responses)
There are 4 different 'Alarm Responses' that can be programmed:
[0] Keypads: If an alarm occurs, the keypad sounder will activate.
[1] Internal Sounders: If an alarm occurs, the internal sounder will activate.
[2] Bells Only: If an alarm occurs, the external sounders will activate.
[3] Signal Digi: If an alarm occurs, the digi will communicate.
[4] Confirm: If an confirmed alarm occurs.
If the Alarm Response for Area A is programmed as 'Start At' "Keypads" and 'Stop at' "Bells
Only" then it will take 15 seconds to go through each alarm responses before stopping at "Bells
Only".
If the Alarm Response is programmed as 'Start At' "Signal Digi" and 'Stop At' "Confirm", all
keypads, internal sounders and bells only will activate the same time as 'Signal Digi' and all will
stop when there is a 'Confirmed Alarm'.
The Enforcer 32-WE can operate on a combined Area basis, for example if both Areas 'A' and 'B'
are set; you may want the process of the alarm responses to change. Therefore The 'If Areas set'
section of this function should be used and select the desired Areas and the Alarm Responses.
Alarm Responses Programming
1. Press or to scroll to 'ALARM RESPONSES'. Press .
2. 'Silent 1st Alarm' will be displayed. Press [ or ] to enable or
disable and press .
3. 'Disable Confirm on Entry' will be displayed. Press [ or ] to
enable or disable and press .
4. 'Area A start at' will be displayed. Press [ or ] to select the
alarm responses and press . Repeat for all alarm notifications.
5. The Engineer menu will be displayed.

4.14 Change Outputs

This function programs all output types, Any output type may be programmed to any of the systems
outputs, including any outputs for wireless bells. Outputs must be used within their rated capacity.
Please see the installation manual.
4.14.1 Output Types
Refer to Appendix D, page 51 for all output type options. Most commonly used input types:
[0003] Intruder Any. [0006] Confirmed Any. [0014] Siren Any. [0016] Strobe Any.
[0018] Unconfirmed Any. [0051] Line Fault. [0052] Mains Fail. [1###] Follow Input.
4.14.2 Endstation Outputs
This function programs the Bell, Strobe and PGM output on the I/O board if connected (see page:
39 for connections).
4.14.3 ZEM Outputs
If a EURO-ZEM8+ or EURO-ZEM8+PSU has been connected to the Enforcer 32-WE (Zone
Expander Modules), this function programs the 4 outputs on each expander. The address of the
expander is required before the output programming. Refer to page: 42 for connections.
4.14.4 Wireless Bells
At default, any wireless bells learnt to the Enforcer 32-WE have the two outputs programmed as
'Siren Any' and 'Strobe Any'. These outputs can be programmed differently if required.
4.14.5 Output Module Outputs
If a EURO-OEM8R8T, or EURO-OEM16R+PSU is connected to the Enforcer 32-WE, they must be
addressed in this function. All output programming is done also here. A maximum of 1 output
expander can be connected to the Enforcer 32-WE. Refer to page: 42 for connections
Enforcer Programming Manual
Page: 20
ALARM RESPONSE?
Silent 1st Alarm
Never
Disable Confirm
On Entry. No [0]
Area A starts at
Digi
[0]
[3]