Figure 6-11 Fan Assembly , G - Overland Data DLT LibraryXpress Series Service Manual

Table of Contents

Advertisement

Removal, Global Control and Capacity Modules
Refer to Figure 6-11.
1.
Remove the cover plate as described in this chapter.
2.
Remove the four M4 x 35 mm Phillips pan head screws and sems washers that
secure the fan to the bulkhead.
3.
Disconnect the fan power cable from the power supply connector.
4.
Remove the fan from the chassis.
Figure 6-11
Replacement, Global Control and Capacity Modules
Refer to Figure 6-11.
1.
Orient the fan and finger guard against the right side of the bulkhead so that the fan
power cable is at the lower left.
2.
Install four M4 x 35 mm Phillips pan head screws with sems washers through the
loops on the finger guard and the holes at the four corners of the fan. Do not tighten
to more than 2-3 in-lb. Excessive pressure will break off the corners.
3.
Connect the fan power cable connector to the power supply connector.
4.
Replace the cover plate as described in this chapter.
Chapter 6 - Parts Removal and Replacement
Fan Assembly, Global Control and Capacity Modules