DESCRIPTION AND OPERATION (Continued)

WIPER BLADES

When the wiper blade rubber element is exposed to
the weather for a long period of time, it tends to lose
wiping ability. Periodic cleaning of the wiper blade
element is suggested to remove the accumulation of
salt and road film. The wiper blades, arms, and
windshield should be cleaned with a sponge or cloth
and a mild detergent or non-abrasive cleaner. If the
blades continue to streak or smear, they should be
replaced. The driver and the passenger blade ele-
ments are 550 mm in length. Only the driver's side
wiper blade has a air foil on it (Fig. 2).
Fig. 2 Driver's Wiper Blade
Condition
Pump runs no fluid flowing.
System operates intermittently.
System output is low.
AIR FOIL

DIAGNOSIS AND TESTING

MULTI-FUNCTION SWITCH – WINDSHIELD WIPER
refer to Group 8J Turn Signals and Hazard Warning
Flashers, for diagnosis and testing of the Multi-Func-
tion Switch.
WINDSHIELD WASHERS
first verify that the windshield washer wire harness
is properly connected to all connectors before starting
normal diagnosis and repair procedures. Refer to
Windshield Washer Diagnosis Chart (Fig. 3).
Possible Cause
(1) No fluid in the reservoir.
(2) Nozzle plugged or frozen.
(3) Broken, loose or pinched hose.
(4) Faulty pump.
(1) Loose wire connection.
(2) Faulty switch.
(1) Pinched hose.
(2) Hose blocked.
Fig. 3 Windshield Washer Diagnosis
WINDSHIELD WIPERS AND WASHERS
To test the multi-function windshield wiper switch,
Whenever a windshield washer malfunction occurs,
Correction
(1) Fill reservoir.
(2) Thaw and check flow if blocked
replace as necessary.
(3) Check flow through hose
connections.
(4) Apply battery voltage to motor
terminals, replace if pump does not
run.
(1) Check wire connections.
(2) Disconnect wire harness use
voltmeter to check switch.
(1) Check flow through hose
connection.
(2) Disconnect hose at nozzle and Y
connector check for flow. Replace as
necessary.