Body Electric
11.9.7 Diagnostic Information and Procedures
11.9.7.1 Diagnosis Description
Refer
to11.9.2 Description and
that it will help to determine the correct diagnostic steps, more importantly, it will also help to determine whether the customer
described situation is normal.
11.9.7.2 Visual Inspection
–
Check installed after market equipment that may affect Central Locking operation.
–
Check the easy to access system components to identify whether there is a significant damage or a potential malfunction.
–
If all door locks are inoperative, check the power supply circuit and the ground circuit for poor connection or open circuit before
replacing bulbs.
11.9.7.3 Symptom List
Symptoms
Mechanical key can not lock / unlock the
door
Central locking switch can not lock / unlock
doors
Operationget familiar with the system functions and operation before start system diagnostics, so
Suspected Faulty Parts
1. Central
Malfunction
2. Left Front Door Unlock / Lock Switch
Poor Connection
3. Wiring
Harness
Connection
4. Ground Poor Connection
5. Harness Malfunction
6. Central Locking Motor Malfunction
7. BCM Malfunction
1. Central
Malfunction
2. Left Front Door Combination Switch
Central Locking Switch Malfunction
3. Wiring
Harness
Connection
4. Ground Poor Connection
5. Harness Malfunction
6. Central Locking Motor Malfunction
7. BCM Malfunction
Locking
Power
Supply
Connector
Poor
Locking
Power
Supply
Connector
Poor
EC718/EC718RV EC715/EC715RV 10/2009
Central Locking
Repair Procedure
1. Check the power supply circuit.
2. Check
wiring
harnesses
connectors.
3. Check ground malfunction
4. Replace the door lock motor.
5. Check the BCM, if necessary, replace
the BCM.
1. Check the power supply circuit.
2. Check
wiring
harnesses
connectors.
3. Check ground malfunction
4. Check the left front door window
switch.
5. Replace the lock motor.
6. Check the BCM, if necessary, replace
the BCM.
11-333
and