Adtech CNC9 Series Maintenance Manual page 53

Table of Contents

Advertisement

1. The system doesn't perform home action after started.
1025
:
4 axis negative soft limit
1026
:
4 axis positive soft limit
1027
:
Z axis negative soft limit
1028
:
Z axis positive soft limit
1029
:
Y axis negative soft limit
1030
:
Y axis positive soft limit
1031
:
X axis negative soft limit
1032
:
X axis positive soft limit
1033
:
4 axis negative hard limit
1034
:
4 axis positive hard limit
1035
:
Z axis negative hard limit
1036
:
Z axis positive hard limit
1037
:
Y axis negative hard limit
1038
:
Y axis positive hard limit
1039
:
X axis negative hard limit
1040
:
X axis positive hard limit
The system has corresponding limit alarm. Please check corresponding limit sensor point or
parameters.
If hard limit occurs, and the appearance of the sensor point doesn't have any problem, enter the
diagnosis mode in manual mode and check the state of the input port in diagnosis mode. If the
state is valid, please eliminate in sequence. Pull out the input IO cable and check whether the
induction disappears. If yes, please check the circuit. If the problem still exists, the internal
optocoupler may be broken. Please contact the supplier.
1041
:
Emergency stop
Emergency stop button of the handheld box interface is valid.
External emergency stop 2 input is valid; check whether IO assignment has conflict or
interference.
Search for corresponding function ports in IO configuration, and then check in input diagnosis.
1042
:
X Servo driver alarm
1043
:
Y Servo driver alarm
1044
:
Z Servo driver alarm
1045
:
A Servo driver alarm
ADTECH9 Series CNC Maintenance Manual