Adtech CNC9 Series Maintenance Manual page 151

Table of Contents

Advertisement

030
X Reset to 360
Y Reset to 360
Z Reset to 360
A Reset to 360
B Reset to 360
C Reset to 360
Range
Unit
Authority
Default
Effective time
Note
031
X Pulse Logic Level (restart)
Y Pulse Logic Level (restart)
Z Pulse Logic Level (restart)
A Pulse Logic Level (restart)
B Pulse Logic Level (restart)
C Pulse Logic Level (restart)
Range
Unit
Authority
Default
Effective time
Note
value of this parameter should be the pulses collected by the encoder for
one cycle divided by 4.
:
0~1
:
:
Super Admin
:
0
:
Instant
:
To set the 360 degree reset when each axis is set to the rotation
:
0~1
:
LOGIC VOLTAGE LEVEL
:
Super Admin
:
0
:
Restart
:
Set the normal voltage level when the pulse is working. If the setting is
different from the normal voltage level required by motor driver, a
direction will have accumulative error during every positive and negative
motion (independent of pulses). Therefore, if the positioning axis of the
machine has accumulative error in a direction, please check whether this
- 146 -
ADTECH9 Series CNC Maintenance Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cnc9640Cnc9650Cnc9960Cnc9816Cnc9810eCnc9810

Table of Contents