Default input port configuration of 99M series XS7 (CNC9960 milling machine)
The digital input interface including the home of every axis (X, Y, Z, A, B, C), the hardware limit signal of every
axis (X, Y, Z, A, B, C), and the definition is as follows:
IN4
B axis home
IN5
Standby input
IN6
Standby input
IN7
Standby input
IN8
Standby input
IN9
Standby input
IN10
Standby input
IN11
Standby input
IN12
Standby input
IN13
Standby input
IN14
B axis negative limit
IN15
B axis positive limit
IN16(XLMT-)
X axis negative limit
IN17(XLMT+)
X axis positive limit
IN18
Y axis negative limit
IN19
Y axis positive limit
IN20(ZLMT-)
Z axis negative limit
IN21(ZLMT+)
Z axis positive limit
IN22
A axis negative limit
IN23
A axis positive limit
Input common end INCOM (24V+, 12V+) connects
INCOM
to internal or external power supply