029
Inp AccSpeed Mode (1: linear acceleration/deceleration 0:S curve acceleration/deceleration)
030
'S' Speed Acceleration
Range
Unit
Authority
Default
Effective time
Note
031
HOME check enable for alarm
032
HOME Check Enable
Range
Unit
Authority
Default
Effective time
Note
033
X diameter prog enable (L series)
Range
Unit
Authority
Default
Effective time
Note
pauses and pre-reads, please increase this value to pre-read more
instructions.
:
:
:
Operation admin or higher
:
:
Instant
:
Used to set the performance of S curve acceleration/deceleration
:
0~1
:
:
Operation admin or higher
:
0, 1
:
Instant
:
Used to set whether prompt user to reset under certain conditions,
ensuring that the user has performed the operation;
If the value is set to 0, it won't check, and will run directly.
:
0~1
:
:
Operation admin or higher
:
1 (L series) /0 (M series)
:
Instant
:
On lathe controller (L series), it is used to set whether the display and
programming of X axis are in radius or diameter;