028
X physial Assign Num<●>
Y physial Assign Num<●>
Z physial Assign Num<●>
A physial Assign Num<●>
B physial Assign Num<●>
C physial Assign Num<●>
Range
Unit
Authority
Default
Effective time
Note
029
X axis encoder wire number
Y axis encoder wire number
Z axis encoder wire number
A axes encoder wire number
B axis encoder wire number
C axis encoder wire number
Range
Unit
Authority
Default
Effective time
Note
:
0~4
:
Pulse port sequence No.
:
Super Admin
:
:
Restart
:
In default mode, the actual number of every axis corresponds to the silk
screen number on the shell. If certain function axis is abnormal, you can
replace the axis through this function. For example, set P2.045 to 4,
P2.048 to 1, then, any operation to X axis will be the operation to A axis
encoder port on the shell.
0: no such axis
1~6: corresponding to 1#-6# axis
:
0~9999
:
Wire number
:
Super Admin
:
2500
:
Instant
:
Set the encoder wires connected to every pulse port (AB phase pulse).
Since four times frequency division is performed for internal transfer, the
- 145 -