034
Default process plane
Range
Unit
Authority
Default
Effective time
Note
035
T code form (compensation number digits)(L series)
Range
Unit
Authority
Default
Effective time
Note
036
Local IP address
037
Subnet mask
038
Default gateway
Range
Unit
Authority
Default
:
G17, 18, 19
:
:
Operation admin or higher
:
G18 (L series)/G17 (M series)
:
Instant
:
Set the default processing plane to XY or XZ; modify the default plane,
so that it isn't need to specify the modal plane value while programming,
and write plane related instructions directly in stead;
:
0~2
:
:
Operation admin or higher
:
2 (L series)
:
Instant
:
Used to set the T value in tool change instruction on lathe controller (L
series); the latter digits indicate the compensation number. In some
conventional programming, people usually use two digits to specify the
compensation number used by corresponding tool number;
For example: T0801 M06 indicates changing the #8 tool and
compensating with #1 length.
:
:
:
Operation admin or higher
:
192.168.0.123
255.255.255.0
192.168.0.1