A Ext Home Enable
B Ext Home Enable
C Ext Home Enable
Range
Unit
Authority
Default
Effective time
Note
038
X Encoder Logic Dir
Y Encoder Logic Dir
Z Encoder Logic Dir
A Encoder Logic Dir
B Encoder Logic Dir
C Encoder Logic Dir
Range
Unit
Authority
Default
Effective time
Note
039
X-axis return-to-zero 2
:
0~1
:
None
:
Super Admin
:
1
:
Instant
:
When mechanical home mode is selected, this parameter determines
whether external deceleration switch should be searched. If this parameter
is set to 0, and P2.015 (servo Z phase enable) is also set to 0, the home
mode sets current point as the home directly in mechanical mode.
0: No
1: Yes
:
0~1
:
None
:
Super Admin
:
0
:
Instant
:
When the logic direction obtained by handheld box encoder is reverse to
the actual motion direction of the axis, set this parameter to perform
in-phase setting.
0: positive direction
1: negative direction
nd
segment leave speed