Adtech CNC9 Series Maintenance Manual page 176

Table of Contents

Advertisement

Effective time
Note
011
Mechanical spindle first gear speed (rpm)
012
Mechanical spindle second gear speed (rpm)
013
Mechanical spindle third gear speed (rpm)
014
Mechanical spindle fourth gear speed (rpm)
Range
Unit
Authority
Default
Effective time
Note
015
Spindle stop delay (ms)
Range
Unit
Authority
Default
Effective time
Note
016
Alarm off spindle enable
Range
Unit
Authority
Default
Effective time
Note
:
Instant
:
When set to ON, the value specified by S in M03Sxxxx instruction is
invalid, and the spindle speed uses the value specified by P5.031.
:
1~1000000
:
rpm
:
Operation admin or higher
:
24000
:
Instant
:
This parameter is used for L version system of lathe, to the maximum
speed of the version, set the maximum speed of each mechanical position
of the lathe spindle relative to M41 M42 M43 M44.
:
0~60000
:
None
:
Operation admin or higher
:
0
:
Instant
:
To set the delay time after the spindle stops
:
0~1
:
None
:
Operation admin or higher
:
0
:
Instant
:
To set whether to automatically turn off the spindle after setting the
- 171 -
ADTECH9 Series CNC Maintenance Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cnc9640Cnc9650Cnc9960Cnc9816Cnc9810eCnc9810

Table of Contents