Adtech CNC9 Series Maintenance Manual page 149

Table of Contents

Advertisement

Unit
Authority
Default
Effective time
Note
027
X Round Setting (Restart)
Y Round Setting (Restart)
Z Round Setting (Restart)
A Round Setting (Restart)
B Round Setting (Restart)
C Round Setting (Restart)
Range
Unit
Authority
Default
Effective time
Note
:
LOGIC VOLTAGE LEVEL
:
Super Admin
:
0
:
Instant
:
Set the effective voltage level of external home sensor switch during
home operation.
Low level
High level
:
0~9999999
:
Pulse
:
Super Admin
:
0
:
Restart
:
Round function is available on hardware version 1.0 or later only;
This function is used to prevent the logic counting of axis exceeding the
maximum counting range (2147483648) and causing overflow error;
Generally, overflow occurs only when the axis is set to rotary. The
system will calculate the corresponding pulse limit according to the gear
ratio of current axis and assign to the ROUND parameter of
corresponding axis, if current axis is set to rotary and uses 360° display
mode after the system getting P2.062~P2.069 parameters. The user can
check the change of this parameter when the rotary axis display function
is enabled. The user can modify the changed parameters, and the finally
displayed number will be effective.
This parameter requires restart to take effect; the corresponding axis must
be rotary and set to 360° display (P2.062~069);