Adtech CNC9 Series Maintenance Manual page 138

Table of Contents

Advertisement

B Fast Speed(mm/min)
C Fast Speed(mm/min)
X axis start rate (mm/min)
003
Y axis start rate (mm/min)
Z axis start rate (mm/min)
A axes start rate (mm/min)
B axis start rate (mm/min)
C axis start rate (mm/min)
X axis acceleration (Kpps)
004
Y axis acceleration (Kpps)
Z axis acceleration (Kpps)
A axes acceleration (Kpps)
B axis acceleration (Kpps)
C axis acceleration (Kpps)
Range
Unit
Authority
Default
Effective time
Note
X Soft PosLimit+(mm)
005
X Soft NegLimit-(mm)
Y Soft PosLimit+(mm)
Y Soft NegLimit-(mm)
:
1~9999, 1~9999, 1~8000
:
mm/min,mm/min,mm/sec
:
Operation admin or higher
:
3000, 200, 1500
:
Instant
:
This parameter is the trapezoid acceleration/deceleration setting and used
for GOO instruction
About start speed, 1-2 rotation motor speed is recommended for step
motor; as above, the machine tool moves 5mm when the motor rotates
one cycle, and the speed is 5-10mm/sec (300-600mm/min). For servo
motor, the start and stop shouldn't have vibration. If this speed is too
high, it will cause vibration during motion, and the step motor will be out
of step.
Parameters affected by the acceleration and start speed include manual
speed, home speed and other non-interpolation motions;
- 133 -