Adtech CNC9 Series Maintenance Manual page 127

Table of Contents

Advertisement

043
Abnormal memory position jump enable
Range
Unit
Authority
Default
Effective time
Note
044
Pause Z to safe altitude
045
Pause A to safe altitude
Range
Unit
Authority
Default
Effective time
Note
046
Program home reference point enable
047
Mechanical home reference point enable
Range
Unit
Authority
Default
Effective time
Note
:
0~2 (corresponding OFF position memory, and status memory)
:
None
:
Operation admin or higher
:
0(OFF)
:
Instant
:
OFF: turn off this function
ON: turn on this function; when turned on, the processing ends because
the processing code has abnormal condition during processing; the
processing can be continued from the break point.
:
OFF workpiece coordinates, machine tool coordinates
:
:
Operation admin or higher
:
0
:
Instant
:
OFF: turn off this function
ON: turn on this function; when turned on, press the [Pause] key during
code processing or execute home operation in home mode, Z axis or A
axis lifts to the safe altitude set by P1.049 or P1.050 automatically
(workpiece coordinates or machine tool coordinates).
:
0~1
:
:
Operation admin or higher
:
0
:
Instant
:
OFF: turn off this function
- 122 -