Effective time
Note
004
Spindle Open Delay
Range
Unit
Authority
Default
Effective time
Note
005
System spindle rotation
Range
Unit
Authority
Default
Effective time
Note
006
Whether close spindle to execute Auto stop
Range
Unit
Authority
Default
Effective time
:
Instant
:
This setting is used to calculate the analog output of the controller, and
suppose that the analog of variable frequency control is in linear control
mode;
This method is to set the rotation to this parameter according to the
variable frequency rotation corresponding to analog 10V, and transfer the
rotation directly later, while the controller will output corresponding
analog voltage according to linear scale automatically.
:
0~10000
:
ms
:
Operation admin or higher
:
0
:
Instant
:
Set the delay before next action or operation after forward or reverse
rotation of the spindle.
:
1~24000
:
rpm
:
Operation admin or higher
:
6000
:
Instant
:
Set the current speed of the spindle.
:
0~1
:
:
Operation admin or higher
:
0
:
Instant
- 169 -
ADTECH9 Series CNC Maintenance Manual