Adtech CNC9 Series Maintenance Manual page 119

Table of Contents

Advertisement

Effective time
Note
010
M Code Delay time (ms)
Range
Unit
Authority
Default
Effective time
Note
011
Line number increment
Range
Unit
Authority
Default
Effective time
Note
012
UART serial port baud rate
Range
Unit
Authority
Default
Effective time
Note
013
Controller ID
Range
Unit
Authority
Default
:
Instant
:
To set to read USB disk processing file directly, and with USB disk
processing online processing function
:
1~9999
:
ms
:
Operation admin or higher
:
100
:
Instant
:
Set the waiting time (unit: ms) after executing M code
:
0~64
:
None
:
Operation admin or higher
:
0
:
Instant
:
While editing G code manually, add a line number Nxxxxx
automatically in a new line;
0 indicates that this function is disabled;
:
9600~115200
:
None
:
Operation admin or higher
:
115200
:
Restart
:
The communication rate setting when DNC or other PC software and
this controller are in RS232 communication mode
:
1~255
:
None
:
Operation admin or higher
:
1