Adtech CNC9 Series Maintenance Manual page 123

Table of Contents

Advertisement

025
Back Home Mode Configuration (BIT)
Range
Unit
Authority
Default
Effective time
Note
026
Arc speed for Radii
027
Arc speed for Speed
Range
Unit
Authority
Default
Effective time
Note
028
Pretreatment Code Setting
Range
Unit
Authority
Default
Effective time
Note
Output signal stops keeping for the seconds specified by P1.023
(reverse phase).
Output signal follows the hertz specified by P1.024 in working state,
and used for oil supply devices. If it is set to 0, the system will keep low
output level.
:
:
:
Operation admin or higher
:
Z – XYABC
:
Instant
:
Set the zero sequence of each axis; up to three sections can be set.
:
:
Coefficient
:
Operation admin or higher
:
50, 100
:
Instant
:
Used to restrict the arc processing speed automatically. This parameter is
valid in pretreatment mode.
The bigger the radius coefficient is, the lower the arc speed is.
The bigger the acceleration coefficient is, the higher the arc speed is.
:
100~5000
:
Instruction line
:
Operation admin or higher
:
500
:
Instant
:
Set the pre-reading instruction lines; if the pretreatment processing
- 118 -