Note
007
Spindle Min Speed(rpm)
Range
Unit
Authority
Default
Effective time
Note
008
Second channel spindle max speed
Range
Unit
Authority
Default
Effective time
Note
009
Second channel spindle speed
Range
Unit
Authority
Default
Effective time
Note
010
Spindle command S value invalid enable
Range
Unit
Authority
Default
:
Set to 0: execute M30 instruction and do not turn off spindle running; set
to 1: execute M30 instruction and turn off spindle running.
:
100~100000
:
rpm
:
Operation admin or higher
:
100
:
Instant
:
Spindle min speed setting
:
1~100000
:
rpm
:
Operation admin or higher
:
24000
:
Instant
:
Set the maximum speed of second channel spindle.
:
1~24000
:
rpm
:
Operation admin or higher
:
6000
:
Instant
:
Set the speed of second channel spindle.
:
OFF ON
:
:
Operation admin or higher
:
OFF
- 170 -
ADTECH9 Series CNC Maintenance Manual