Range
Unit
Authority
Default
Effective time
Note
022
Lubricant Pressure Open(min)
023
Lubricant Pressure Keep(sec)
024
Lubricant Pressure Out Freq(Hz)
Range
Unit
Authority
Default
Effective time
Note
:
0~1
:
None
:
Operation admin or higher
:
0
:
Instant
:
Control mode corresponding to spindle S code (frequency conversion
mode)
0 : Analog output
1: Section speed regulation (4-digit code determined by output port
configured by spindle parameters P6.014 ~ P4.017), as below:
P6.014------S0
P4.015------S1
P4.016------S2
P4.017------S3
In analog output mode, the analog voltage is:
V=S/MaxRPM
S is the rotation set by the user, and MaxRPM is the maximum rotation
of spindle set by the parameter (P4.017);
In switching quantity mode, constitute block 0-15 according to
four-digit code to output; S code value is restricted to 0-15;
:
:
:
Operation admin or higher
:
0
:
Instant
:
Set the schedule start and holding time of the automatic oil pump of the
system
Schedule open setting is that the settings of P6.045 oil pump output
ports when the timing reaches specified value after the system starts and
times.