Note: The splitter terminal GND and +24V are used for power supply of external proximity sensor switch. Every
four input points share a group, and the maximum operating current of each group of power supply terminals is
200MA. Except common terminal 24V or GND is selected for IN08-IN15 by J34, the common terminal of all
other input points is +24V, and the status of the input point inverts when all input terminals are connected to
GND.
ET102A splitter function definition
Terminal
Area
No.
J38
POWER
J38
J38
IN03-IN00
Port Name
+24V
GND
IN00
ADTECH9 Series CNC Maintenance Manual
Function
24V power supply output terminal
24V power supply output GND terminal
IN00
- 221 -