Range
Unit
Authority
Default
Effective time
Note
054
IO Conf in RESET 00~31
055
IO Conf in RESET 32~63
056
IO Conf in RESET 64~95
057
IO Conf in RESET 96~127
058
IO Conf in RESET 128~159
059
IO Conf in RESET 160~191
060
IO Conf in RESET 192~223
Range
Unit
Authority
Default
Effective time
Note
:
0x00000000~0xFFFFFFFF
:
:
Super Admin
:
0
:
Instant
:
Used to configure IO detection effective voltage level, 0: Low 1: High.
Use binary system to configure in positions.
For example: P6.050:10, is 00000000 00000000 00000000 00001010 in
binary system;
which indicates that among input ports IN32 ~ IN63, IN33 IN35 IO
detection effective voltage level is high, while other IO detection
effective voltage levels are low.
:
0x00000000~0xFFFFFFFF
:
:
Super Admin
:
0
:
Instant
:
Used to configure the IO that the system needs to reset when there is
alarm. 0: No; 1: Yes
Used to configure the IO signal that the system needs to reset when there
is alarm.
For example: P6.53:10, is 00000000 00000000 00000000 00001010 in
binary system;
which indicates that among OUT32 ~ OUT63, OUT33 is reset when the
system resets or alarms, OUT35 turns off, while other output ports are